Contact Angle Measurement Equipment

Precisely Measure Surface Wettability with KeyLink Contact Angle Goniometer

As a leading manufacturer of plasma surface treatment systems, Keylink offers advanced contact angle measurement equipment to help you verify surface cleanliness, validate plasma treatment effects, and ensure optimal adhesion for your materials.

Your Adhesion Solution Starts Here: Contact Angle Testing & Plasma Treatment

  • Problem:Poor adhesion often leads to product defects, costly rework, and material waste. Without a reliable testing method, it’s difficult to control surface quality and ensure consistent bonding.
  • Solution:Keylink provides a complete approach. First, our Plasma Treatment System effectively cleans and activates your material surface, removing invisible contaminants. Then, through precise contact angle testing, our Contact Angle Measurement Device verifies whether the treatment has achieved the desired effect. This two-step process ensures that surfaces are fully prepared for strong adhesion in bonding, printing, or coating applications.

What is the Angle of Contact?

Contact angle meters, also known as tensiometers or goniometers, are widely used across various industries to measure the contact angle of a liquid on a solid surface, providing insights into wettability, surface energy, and adhesion properties. Key industries employing these instruments include materials science, coatings, pharmaceuticals, electronics, and automotive manufacturing.

Contact angle meters are often used to evaluate the effectiveness of plasma treatment by measuring the wettability of a surface after treatment. Plasma treatment modifies the surface properties of materials, and contact angle measurements provide a quantitative assessment of these changes, indicating the degree of hydrophilicity or hydrophobicity.

The basic principle of a contact angle meter involves placing a small droplet of the liquid onto the solid surface and then using a camera and analysis software to measure the angle formed by the droplet where it meets the surface. Optical tensiometers typically have a camera, a dispenser for creating the droplet, a sample stage, and a light source.

The contact angle (θ) is the angle formed between the liquid-solid interface and the liquid-vapor interface at the droplet’s edge. It indicates:

The contact angle (θ) is the angle formed between the liquid-solid interface and the liquid-vapor interface at the droplet’s edge. It indicates:

  • Hydrophilicity (θ < 90°) – The surface is wettable (water spreads easily).
  • Hydrophobicity (θ > 90°) – The surface repels water (droplets bead up).

Guarantee Material Performance with Accurate Contact Angle Analysis

Speak with our technical experts to discover how the right Contact Angle Goniometer can solve your surface wettability challenges and validate your plasma treatment effectiveness.

KeyLink Contact Angle Tester: CA01 vs. CA02

CA01: The Essential Manual Tester

Ideal for R&D labs and basic quality control, the CA01 offers a straightforward, manual operation with high accuracy. You manually control the droplet and use the powerful CA V2.0 software for analysis, making it a cost-effective choice for a wide range of applications.

CA02: The Automated Production-Ready System

The CA02 is an automatic optical contact angle measuring instrument designed for high-volume, repetitive testing. Its automated droplet dispensing and real-time liquid level detection ensure consistent and precise measurements with minimal operator intervention. This model is perfect for busy manufacturing environments like those in mobile phone or glass production.

Check the specs and see which model fits your testing needs!

FeatureCA01 Basic ModelCA02 Automatic Model
Dropping ModeManualAutomatic
Dropping Accuracy0.1 μL0.1 μL
Weight10KG12KG
Max Shooting Speed80 frames/s80 frames/s
Camera Resolution1280x10241280x1024
Angle Range0° to 180°0° to 180°
Angle Precision0.1°0.1°
Surface Energy Method7 methods available7 methods available
System RequirementWindows 10 (64-bit)Windows 10 (64-bit)

Core Functionality: Go Beyond Just Angle Measurement

Keylink’s goniometers come with the CA V2.0 software, providing a comprehensive analysis tool for material professionals.

Static & Dynamic Analysis

The software supports both static and dynamic contact angle measurement. You can perform static analyses using methods like the sessile drop method or dynamic analyses to measure advancing and receding angles. This includes contact angle hysteresis, which is closely related to a surface’s wetting properties.

Automated Fitting Algorithms

Our system offers multiple calculation methods, including Circle, Ellipse, three-point, and five-point fitting, with an automatic fitting feature for accurate, ms-level one-key measurement. This reduces manual error and speeds up your quality control process.

Surface Energy Analysis

The software can calculate surface energy from contact angle using a pre-installed database of 37 liquids and multiple estimation methods like Fowkes, OWRK, and Acid-Base Theory. You can obtain detailed data on dispersion, polar forces, and hydrogen bonding to better understand your material’s properties. This makes it ideal for those who want precise surface energy calculation from contact angle data.

Dyne Test of water surface angle changing

What Does Contact Angle Tester Used For?

Our contact angle measurement equipment is widely used to evaluate surface properties across various industries:

Why Choose KeyLink for Contact Angle Testing

KeyLink contact angle testers provide high-accuracy, reliable measurements for surface wettability, adhesion, and performance, supporting both R&D and industrial quality control.

Our contact angle measurement equipment uses dry, non-invasive optical methods, preserving original material properties while delivering precise surface insights.

Advanced software calculates contact angles, surface energy, and hydrophobicity, enabling repeatable, consistent results with detailed reporting for every sample.

Systems suit high-volume labs and production lines, integrating seamlessly into workflows for fast, reliable contact angle testing and process verification.

KeyLink contact angle goniometers handle metals, plastics, ceramics, and coatings, offering versatile evaluation across multiple industries and applications.

Backed by ISO, CE, UL, and ETL certifications, our products come with 12-month warranty, technical guidance, and dedicated after-sales service worldwide.

Enhance Product Reliability with High-Precision Contact Angle Measurement

Request a personalized quote for our Contact Angle Goniometer and start performing precise contact angle measurement to ensure optimal adhesion and improve your quality control.

FAQ Section

 The primary difference is the dropping mechanism. The CA01 is a manual model where the operator controls liquid dispensing, ideal for basic tests. The CA02 is an automatic model with a dedicated auto-dispensing system for more consistent, high-volume testing in manufacturing environments.

Yes, our equipment is compatible with Windows 10 64-bit systems. We recommend a computer with an I3 2.0GHz or higher CPU and at least 4G of RAM for optimal performance.

The software can measure dynamic contact angles, including advancing and receding angles. It also calculates contact angle hysteresis, which reflects the difficulty of a droplet rolling off a surface. This is achieved by either adding/subtracting liquid or using a tilting plate method.

Yes, our software includes a dedicated module for surface energy calculation from contact angle. It uses various theoretical methods and a pre-installed liquid database to estimate surface free energy and its components, which cannot be measured directly.

The angle of contact definition refers to the angle formed at the junction of a liquid, solid, and air interface. For example, what is angle of contact in surface tension is the angle that determines whether a liquid wets a solid. What is contact angle of water is a commonly asked question: water typically shows a contact angle of ~0° on clean glass (complete wetting) and higher on hydrophobic coatings.

Researchers use contact angle testing to study:

  • Contact angle of water on aluminum to check oxidation and cleanliness.
  • Contact angle of water on copper for corrosion resistance.
  • Contact angle of mercury to understand extreme wetting.

Get Advanced Vacuum Plasma Solutions

Let us help you select the perfect model; contact us today for a detailed consultation on our contact angle measurement equipment and achieve repeatable results in your lab or production line.

+8618958862656

Get an expert on the phone

info@keylinktech.com

Write us what we can do for you

Request A Quotation

You know exactly what you’re looking for

 Send us a message!
Our system experts are happy to assist you.